Asset intelligence for energy and wildfire risk

Inspection records that hold up with regulators, insurers, buyers and lenders.

Tessera captures radiometric thermal and survey-grade imagery of solar plants, battery-storage sites and wildfire-exposed property, then turns it into a located, analyst-reviewed record of asset condition that you can compare year over year.

Every finding carries a location, a thermal and visual image pair, a time stamp and a reviewer.

IEC TS 62446-3Aerial thermography method for photovoltaic plants
600 W/m²Minimum plane-of-array irradiance for solar captures, logged per flight
0–5 · 30 · 100 ftDefensible-space zones mapped from every wall, per PRC 4291 and the 2026 Zone 0 rules
100%Of reported findings reviewed by an analyst before delivery
01Who we serve

One record, read by everyone with a stake in the asset

Operators use it to fix things. Owners, lenders and insurers use the same record to understand condition and risk. We build each deliverable for the person who has to act on it.

A

Asset owners and IPPs

Annual condition baselines across solar and storage portfolios.

  • Site-by-site comparability
  • Revenue-at-risk estimates
  • Warranty and claim support
B

O&M providers

Located, prioritized work lists that drop into your CMMS.

  • Findings by block, string, module
  • Asset-ID matched registers
  • Repair verification flights
C

Lenders, investors and engineers

Independent field data for acquisitions, refinancings and portfolio reviews.

  • Pre-close condition scans
  • Data packages for your independent engineer
  • No ties to repair vendors
D

Insurers and brokers

Documented mitigation for wildfire-exposed homes and communities.

  • Zone 0 to Zone 2 condition by parcel
  • Dated before-and-after records
  • Community-level summaries
E

HOAs and communities

A readiness report for every home and a plan for the board.

  • Owner-level fix lists
  • Common-area findings
  • Firewise USA support
02Programs

Recurring programs, scoped and priced per site

Condition data is most valuable when it's collected the same way every year. Each program has a fixed scope, a fixed price and a defined data package.

Solar owners and O&M

Solar Site Annual Program

A full-plant radiometric thermal survey to IEC TS 62446-3, flown in the spring and summer irradiance window.

  • Anomaly register by block, string and module
  • Severity classes, repair priorities and revenue at risk
  • Reflight of any rows lost to cloud shadow
  • Pre-season vegetation map of the site
Service details →Request a solar proposal →
Battery-storage owners and operators

Battery-Storage Site Program

A pre-summer exterior thermal and visual survey of enclosures, inverters and transformers, flown during a discharge window.

  • Cooling faults, hot terminals and seal leaks flagged
  • Findings matched to your asset IDs
  • Entries formatted for your maintenance logbook
  • Fixed standoff from energized equipment
Service details →Request a storage proposal →
Lenders, investors and independent engineers

Transaction Condition Survey

An independent pre-close thermal and visual survey of a plant or portfolio, delivered in a format your independent engineer and counsel can use.

  • Full-plant anomaly register with severity
  • Estimated energy and revenue at risk
  • Complete raw data package and chain of custody
  • Timed to your diligence calendar
Service details →Discuss a transaction →
HOAs, Firewise USA sites and home sellers

Defensible-Space Program

A spring mapping flight over the community, a readiness report for every home and a board summary, with a recheck flight before fire agency inspections. Single-home pre-listing reports are available year-round.

  • Zone 0, 1 and 2 checklist for each parcel
  • Numbered fix list with photos, timing and cost guide
  • Common-area findings and season plan for the board
  • Readiness documentation, not the official inspection
Service details →Request a community proposal →

Utility inspection support

Subcontract field capacity for utility inspection programs, flown to the prime contractor's flight plans and data specifications, October through March.

Service details →Discuss utility work →
03Platform

Software does the screening. Analysts sign the findings.

Tessera's own processing pipeline turns each flight into a consistent, located record. Automation means every module, enclosure and parcel gets looked at. A trained analyst reviews every flag before it reaches a report.

01 · CAPTURE

Fly to specification

Radiometric thermal and RGB imagery with RTK positioning, inside the irradiance, wind and airspace limits for the job.

02 · DETECT

Screen everything

Automated detection flags thermal anomalies and defensible-space conditions across the full site, not a sample.

03 · REVIEW

Analyst sign-off

Each flag is confirmed or rejected, measured, classed by severity and given a recommended action.

04 · RECORD

Deliver and compare

A signed report and data package, structured to line up with prior seasons and across sites.

Detection

Thermal anomaly screeningModules, strings, enclosures and inverters, screened against their peers.
Defensible-space pre-screeningEach parcel's zones checked for mulch, canopy, dry fuel and other common issues.

Reporting

Standardized reportsThe same severity classes and format every season, with every finding located and illustrated.
Community-scale outputOne flight becomes an owner report for every home plus a board summary.

Portfolio

Year-over-year trackingWhat was fixed, what's getting worse and where to spend next, season to season.
Portfolio screeningA first look across many sites to decide where inspections matter most.
04Deliverables

A report for decision-makers, and the data behind it

Every engagement includes the full data package, in open formats your team, your engineer or your GIS can use directly.

Signed reportSummary, findings, severity, recommended actions and sign-offPDF
Findings registerEvery finding with coordinates, asset IDs, severity and statusCSV · XLSX
GIS layersFindings, zones and site boundaries for your mapsGeoJSON · KML
OrthomosaicsThermal and RGB imagery of the whole site, georeferencedGeoTIFF
Image pairsA thermal and a visual image for each findingJPEG · radiometric JPEG
Capture logFlight times, irradiance and weather conditions for the recordPDF · CSV
05Quality and governance

Built to be relied on by people who weren't on site

A finding is only useful if someone else can check it. Our process is written down, repeatable and documented in every delivery.

Defined methods

Solar thermography to IEC TS 62446-3. Defensible-space checklists follow CAL FIRE guidance, PRC 4291 and the Zone 0 rules adopted in 2026.

Two-stage review

Automated screening, then analyst confirmation of every reported finding. Uncertain items are marked for ground check rather than guessed.

Traceability

Every finding carries its location, image pair, capture time and reviewer. Capture conditions are logged and delivered with the report.

Independence

We inspect and report. We don't sell repairs, landscaping, panels or equipment, so findings are never shaped to create work.

Flight operations

FAA Part 107 operations with airspace authorization checked before every flight. Energy and utility work is flown on US-made aircraft.

Site safety

Site orientations, NFPA 70E-aware procedures and fixed standoff distances for battery-storage and substation work.

Data ownership

You own your data. Delivery is encrypted, access is limited to named recipients and retention follows your contract.

Privacy

Written owner or HOA consent before community flights, advance notice to residents and no imaging of people. Owner reports go only to that owner.

Insurance and contracting

Certificates of insurance, a W-9 and our standard services agreement are provided with every proposal.

06Sample reports

Review the deliverable before you engage

Four complete sample reports in the format we deliver.

Cover and defect map page of the sample solar thermal inspection report
SAMPLE · SOLAR

Solar thermal inspection

A 20 MW single-axis plant: 64 anomalies mapped to block, string and module, severity classes, estimated revenue at risk and a repair priority list. 7 pages.

Open PDF
Cover and asset temperature page of the sample battery-storage site scan
SAMPLE · STORAGE

Battery-storage site scan

A 100 MW / 400 MWh site surveyed during discharge: enclosure and inverter temperatures, five findings and logbook-ready entries. 5 pages.

Open PDF
Cover and neighborhood map page of the sample HOA community readiness report
SAMPLE · COMMUNITY

HOA community readiness

The board report for a 42-home community: readiness by home, the most common fixes, group work-day savings, common-area items and the season plan. 6 pages.

Open PDF
Cover and parcel map page of the sample defensible-space readiness report
SAMPLE · PARCEL

Homeowner parcel report

The report each owner receives: zone map, 18-item checklist and eight numbered fixes with timing and cost guidance. 5 pages.

Open PDF

Samples use fictional sites and illustrative data. They are not records of real inspections.

08Company

An inspection firm built around the record, not the flight

Most aerial work ends with pictures. Ours ends with a record: what was found, exactly where, how serious it is and what to do next, in a form an operator, a board, an insurer or a lender can rely on.

Traceable

Nothing in a report is a judgment you can't check against the imagery.

Consistent

Same method, severity classes and format every season and every site.

Independent

No repair, product or contractor relationships that bias findings.

Regional

Based in Los Angeles County, so rechecks and follow-up flights are quick.

Company information

Legal entity
CCV Ventures II LLC, a Wyoming limited liability company
Business name
Tessera Asset Intelligence
Founded
2026
Base
Los Angeles County, California
Coverage
San Luis Obispo County and the Carrizo Plain, Kern County, and Los Angeles, Ventura, Orange, Riverside, San Bernardino and San Diego counties
Contact
[email protected]
09Request a proposal

Tell us about the site or portfolio

We reply within one business day with questions or a fixed-scope proposal. Spring solar and defensible-space dates fill first.

  • Solar and storage: capacity, location and your O&M or diligence timeline.
  • Transactions: number of sites, closing date and who receives the data.
  • Communities: number of homes and your fire agency's inspection month.
  • Home sellers: address and target listing date.
We use your details only to respond. See our privacy policy.
10Questions

Common questions

What standards do you work to?

Solar thermography follows IEC TS 62446-3, including its minimum irradiance requirement. Defensible-space checklists follow CAL FIRE guidance, PRC 4291 and the Zone 0 rules the State Board of Forestry adopted in 2026. Each report states the method used.

Can you support an acquisition or refinancing?

Yes. A Transaction Condition Survey gives buyers, lenders and their independent engineers a full-plant anomaly register, estimated energy at risk and the complete raw data package, scheduled around the diligence calendar. We are independent of the seller and of repair contractors.

Who owns the data, and how is it delivered?

You do. We deliver the full data package with every report through an encrypted link to the recipients you name, and keep copies only as your contract allows.

Does a Tessera report replace the fire agency's defensible-space inspection?

No. Only your local fire agency can inspect and certify defensible-space compliance, including the documentation home sellers in High and Very High Fire Hazard Severity Zones must provide. Our readiness report shows what to fix before that inspection.

Will you fly over neighbors?

For community work we get written consent, notify residents before the flight, plan routes to avoid sustained flight over people and do not image people. Owner reports go only to that owner and to the HOA as the owner's agreement allows.

How quickly is the report delivered?

Within 5 business days of the flight for most engagements. Critical findings, such as a string not producing or a hot terminal, are reported the same day.